- New
Three-phase hybrid inverter 40kW Solis S6 4 MPPT DC switch photovoltaic solar
€4,436.90 Vat excl.
The Solis S6-EH3P40K-H series three-phase energy storage inverter is designed for commercial PV energy storage systems. This type of product features independent generator output and multiple inverter parallel operation.
Three-phase hybrid inverter 40kW Solis S6 3 MPPT DC switch
The Solis S6-EH3P40K-H series three-phase energy storage inverter is designed for commercial PV energy storage systems. This type of product features independent generator output and multiple inverter parallel operation.
They also offer independent generator outputs, high current charging and discharging capabilities, and various flexible load capacity options, including UPS-level switching. They easily adapt to three-phase unbalanced loads and half-wave loads, ensuring highly reliable power supply.
Main features
- 2 seconds of 160% overload capability;
- Supports Peakshaving features in "self-use" and "generator" modes;
- Supports Unbalanced and Half-Wave Loads on both the Grid and Backup Port;
- Support 200% DC/AC ratio, make full use of PV charging, provide long backup hours;
- Battery real-time monitoring , remote upgrade, and battery healing function to prolong battery life;
- Supports a maximum input current of 20 A, making it ideal for all high-power PV modules from any brand;
- A wide battery voltage range accommodates the prevalent high-voltage lithium batteries found in the market;
- Battery charging/discharging current 140A/70A+70A, suitable for 280Ah cell standard 0.5C application condition.
For more details, download the following documents:
- Datasheet [Download]
Technical features:
| DC Input (PV Side) | |
| Recommended maximum PV array size | 80 kW |
| Recommended maximum PV input power | 80 kW |
| Absolute maximum voltage | 1000 V |
| Nominal voltage | 600 V |
| Start-up voltage | 180 V |
| MPPT voltage range | 150 - 850 V |
| Maximum input current | 4 x 40 A |
| Maximum short-circuit current | 4 x 60 A |
| Number of MPPTs / Maximum number of strings | 4 / 6 |
| Battery | |
| Battery type | Lithium-ion |
| Permitted voltage range | 150 - 800 V |
| Maximum charge / discharge power | 44 kW |
| Maximum charge / discharge current | 70 A x 2 |
| Number of battery inputs | 2 |
| Maximum charge / discharge power per input | 35 kW |
| Communication | CAN / RS485 |
| AC Output (Grid Side) | |
| Rated output power | 40 kW |
| Maximum apparent output power | 40 kVA |
| Nominal grid voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V |
| Nominal grid frequency | 50 Hz / 60 Hz |
| Rated grid output current | 60.8 A / 57.7 A |
| Maximum output current | 60.8 A / 57.7 A |
| Power factor | > 0.99 (0.8 leading - 0.8 lagging) |
| THDi | < 3% |
| AC Input (Grid Side) | |
| Maximum AC transmission current | 121.6 A / 115.4 A |
| Nominal input voltage | 3/N/PE, 220 V / 380 V, 230 V / 400 V |
| Nominal input frequency | 50 Hz / 60 Hz |
| AC Output (Back-up) | |
| Rated output power | 40 kW |
| Maximum apparent output power | 1.6 times rated power, 2 s |
| Backup switching time | < 10 ms |
| Rated output current | 60.8 A / 57.7 A |
| THDv (@linear load) | < 2% |
| Efficiency | |
| Maximum efficiency | 97.8% |
| EU efficiency | 97.4% |
| Maximum BAT efficiency charged from PV | 98.5% |
| Maximum BAT efficiency charged / discharged via AC | 97.5% |
| Protection | |
| Anti-islanding protection | Yes |
| Output overcurrent protection | Yes |
| Short-circuit protection | Yes |
| Integrated DC switch | Yes |
| DC reverse polarity protection | Yes |
| DC / AC surge protection | Type II / Type II |
| Integrated AFCI 2.0 | Optional |
| General Data | |
| Dimensions (W × H × D) | 530 × 880 × 290 mm |
| Weight | 73 kg |
| Topology | Transformerless |
| Self-consumption (night) | < 35 W |
| Operating ambient temperature range | -25 ~ +60°C |
| Relative humidity | 0 - 95% |
| Protection degree | IP66 |
| Cooling method | Intelligent fan cooling |
| Maximum operating altitude | 4000 m |
| Grid Connection Standards | |
| Grid connection standards | G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1/EN 50549-10, VDE 0126/UTE C 15/VFR:2019, NTS 631/RD 1699/RD 244/UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA, PORTARIA Nº 140, DE 21 DE MARÇO DE 2022 |
| Safety / EMC Standards | |
| Safety / EMC standards | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011 |
| Features | |
| PV connection | MC4 quick connector |
| Battery connection | Terminal connectors |
| AC connection | Terminal block |
| Display | 7.0" LCD display and Bluetooth + APP |
| Communication | CAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN |
- MPPT number
- 4
- Typology
- Three-phase
- Inverter power
- 40kW