Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic
Smart Battery Protect 100A 12/24V Victron Energy Battery Protection Photovoltaic

Smart Battery Protect 220A 12/24V Victron Energy Battery Protection Photovoltaic

BPR122022000
€140.12
VAT included 22 %

€114.85 Vat excl.

Smart BatteryProtect

The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

 

Smart Battery Protect 220A 12/24V

Smart BatteryProtect

The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual).

If required, Bluetooth can be disabled.

Technical features

Model: Smart BatteryProtect 220A

  • Maximum continuous load current: 220A
  • Peak current (during 30 seconds): 600A
  • Operating voltage range: 6 –35V
  • Current consumption:
    • BLE On: When on: 1,4 mA When off or low voltage shutdown : 0,9 mA
    • BLE Off: When on: 1,2 mA When off or low voltage shutdown : 0,7 mA
  • Alarm output delay: 12 seconds
  • Maximum load on alarm output: 50 mA (short circuit proof)
  • Load disconnect delay: 90 seconds (immediate if triggered by the VE.Bus BMS)
  • Load reconnect delay: 30 seconds
  • Default thresholds:
    • Disengage: 10,5V or 21V
    • Engage: 12V or 24V
  • Operating temperature range: Full load: -40°C to +40°C (up to 60% of nominal load at 50°C)
  • IP rating:
    • Electronics: IP67 (potted)
    • Connections: IP00
  • Connection: M8
  • Weight: 0,8Kg
  • Dimensions (HxWxD): 62 x 123 x 120 mm

Connections

Other functions

Protects the battery against excessive discharge and can be used as a system on/off switch
The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. The on/off input can be used as a system on/off switch.

12/24V auto ranging
The Smart BatteryProtect automatically detects system voltage one time only.

Bluetooth: programming made easy
When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual). If required, Bluetooth can be disabled.

A special setting for Li-ion batteries
In this mode the BatteryProtect can be controlled by the VE.Bus BMS.

Ultra-low current consumption
This is important in case of Li-ion batteries, especially after low voltage shutdown.

Over voltage protection
To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16.3V respectively 32.6V.

Ignition proof
No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.

Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the battery voltage drops below the preset level. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.

System on/off
a. ON when the L and H terminal are interconnected (switch or relay contact)
b. ON when the L terminal is pulled to battery minus (V< 3.5V)
c. ON when the H terminal is high (2.9V < VH < Vbat)
d. OFF in all other conditions

   Downloads

DATASHEET EN [LINK]
USER MANUAL [LINK]

  Customer Service

0882 22 82 47
[email protected]
Product Code
BPR122022000
Battery-connection
M8
Dimensions (D x W x H)
62 x 123 x 120 mm
Net Weight
0,5Kg
8719076041269