CHARGE CONTROLLER TRISTAR TS-45 12-24-48V morningstar PHOTOVOLTAIC SOLAR View larger

Solar charge controller PWM 45A 12/24/48V TriStar MorningStar Photovoltaic Solar


€ 214,10 tax incl.


€ 194,64 tax excl.

TS-45

New

Morningstar’s TriStar Controller is a three-function controller that provides reliable solar battery charging, load control or diversion regulation.

More details

5 Items

In Stock

Product Code TS-45
Technology (MPPT - PWM) PWM
Nominal system voltage (VDC) 12 / 24 / 48 VDC Auto work
Rated Battery Current 45A
Self-consumption 7.5mA
Terminal 35mm²
Working temperature –55°C to +85°C
Overall dimension 26x12.7x7.1 cm
Net weight 1.6 kg
Image centered Grand Chamber Description
The TriStar uses advanced technology and automated production to provide exciting new opportunities at a competitive price.

The regulator is UL listed and is designed for residential solar systems for professional applications.
Technical Data Section
Model
TS-45

45.
  • Max load current 45.
  • System voltage 12/24/48 V
  • Digital Display you
  • Remote Display you
  • Remote temperature sensor you
  • Minimum operating voltage 9V battery
  • Maximum Voc of solar panel 125V
  • Maximum operating voltage 68V
  • Own Consumption less than 20mA
  • Cable terminals 35 mmq
  • Casing White powder coated steel
  • Heat resistance Electrolytically black anodized aluminium
  • Dimensions 256 x 124 x 58 mm
  • Weight 1.8 Kg
  • Dropdown lists technical specificationsUl Listed (UL 1741) and cUL Listed (CSA-C 22.2 No. 107.1)
  • Conforms to the U.s. National Electric Code.Complies with EMC and LVD standards for CE marking.
  • Total protection with automatic resetting and manual.
    • Seven charge programs or selectable load by means of DIP switches.
    • Adjustments possible via RS-232 connection to a PC.
    • Self-check continues with reporting of incidents.
    • LED indicators and function buttons.
    • Terminals for conductors of 35 mm² (2 AWG).
    • Includes a terminal of battery voltage detection
    • Digital tools options (mounted on the TriStar or away).
    • Standard Features
    • Performance up to 50° C and meets UL regulations;
    • Possibility of 7 different selectable adjustments or LVD placements with DIP switches;
    • RS-232 standard position enables a wide range of ad hoc picks
    • DB-9 connector, 9600 baud
  • Designed for PCs and PDAs
    • Can be used on: positions the control and parameters to adjust, memory with 30 days (feature to implement), remote monitoring and control (feature to implement)
    • Continuous self. If a fault is detected, the failure is indicated on the digital display and indicated by the LEDs
    • A reset button errors or failures, starts or stops the Equalization of batteries (charging control function) or LVD ignores (function of charge control)
    • Solid state at 100% to get full reliability in extreme environments
    • Microprocessor control for more extensive capabilities
    • Casing suitable for larger electric wires
    • Reduced voltage drops
    • Estimated duration of 15 years
    • Charge protection
    • Reverse polarity protection (in any combination)
    • Protection for short-circuits and load PV
    • All connectors have short-circuit protection
    • Protection against overcurrents solari cargo or
  • Lightning protection and surge through momentary surge suppressors from momentary 4500W
    • High temperature protection via automatic current reduction or complete shut down
    • Function of charge Control
    • Electronic short circuit protection and overload protection with automatic reconnection
    • Starts all loads including inductive loads (displays, pumps) without damage to the regulator
    • Allows current inputs up to 300A
    • The LVD has 4 minutes late to avoid disconnections are wrong
  • LEDs and LCDs LVD regulations and these
    • The LVD is normally compensated to avoid disconnection errors
    • Autodisconnect protected load to high voltages
    • Secure load from surges photovoltaics when the battery is removed
    • Display options
    • Voltage accuracy is 0.2%
    • Current accuracy is 1.0%
    • The display can be mounted to the controller by removing the cover of the controller
    • 2 x 16 backlit
  • Attaches to the controller with RJ-11 connector for easy installation
    • Includes 4 buttons to display "up-down" and "right-left"
    • Indicates the results of diagnostics and system information the regulator setting points
    • Digital Display for the remote controller mounting (in another room): on a wall to wall mounting or mounting on a junction box.It installs with RJ-11.
    • Diversion functions
    • Can be used for solar, wind or hydroelectric
    • To protect against overloads, the excess current is diverted from the primary battery to a secondary battery or otherwise to a resistive load in alternating current.
    • Environmental Specifications
    • Operating environment temperature: -40° C +50° C to 60° C (tolerance of 20 per cent)
  • Holding temperature: -55° C +85° C
    • Operating temperature:-digital display30° C-+85° C
    • Humidity: 100% (no condensation)
  • Tropicalization: Conformal coating on both sides of the electrical circuit, electrolytically anodized aluminium, steel casing, powder coated stainless steel connectors
    • Picture section connection diagram
    • VAT 10% line On this product you can enjoy 10% VAT
    • Click here to download the 10% VAT and send to the address [email protected] or by fax at 0882243119


Path: > > > > > Solar charge controller PWM 45A 12/24/48V TriStar MorningStar Photovoltaic Solar