Product successfully added to your shopping cart
Quantity
Total
There are 0 items in your cart. There is 1 item in your cart.
Total products (tax excl.)
Total shipping (tax excl.) To be determined
Total (tax excl.)
Continue shopping Proceed to checkout
POWER ONE PVI-6000-TL-SINGLE-PHASE OUTD View larger

INVERTER ABB 6KW SINGLEPHASE PVI-6000-TL-OUTD ON-GRID EXCHANGE ON SITE


€ 987,93 tax incl.


€ 898,12 tax excl.

PVI-6000-TL-OUTD

New

Ideal inverter for the realization of residential and commercial photovoltaic systems connected to the network in exchange mode on site.

More details

1 Item

Warning: Last items in stock!

Product Code PVI-6000-TL-OUTD
Absolute maximum DC input voltage (Vmax,abs) 600 V
Start-up DC input voltage (Vstart) 200 V (adj. 120...350 V)
Operating DC input voltage range (Vdcmin...Vdcmax) 0.7 x Vstart...580 V (min 90 V)
Rated DC input voltage (Vdcr) 360 V
Rated DC input power (Pdcr) 6200 W
Number of independent MPPT 2
Maximum DC input power for each MPPT (PMPPTmax) 4000 W
DC input voltage range with parallel configuration of MPPT at Pacr 180...530 V
Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax 18.0 A
Maximum input short circuit current for each MPPT 22.0 A
Number of DC inputs pairs for each MPPT 2
DC connection type Tool Free PV connector WM / MC4
Rated Power W 6200 W
Waveform Pure Sine Wave
Battery Voltage V 360 V
Typology Single-phase

Inverter Abb 6kw Single-phase without Transformer

PVI-6000-TL-OUTD

Inverters for photovoltaic systems connected to the network in exchange on site

Ideal inverter for the realization of residential and commercial photovoltaic systems connected to the network in exchange mode on site. The inverter has a double input section to process two strings with independent MPPTs. The wide input voltage range makes the inverter suitable for low power installations with smaller strings. This outdoor inverter is completely sealed and is able to withstand even the most extreme environmental conditions.

Highlights

  • Single-phase output
  • Transformerless topology
  • Each inverter is set on specific grid codes which can be selected in the field
  • Dual input section with independent MPP tracking, allows optimal energy harvesting from two sub-arrays oriented in different directions
  • Wide input voltage range

Technical specifications

INPUT

  • Absolute maximum DC input voltage: 600 V
  • Start-up DC input voltage: 200 V
  • Operating DC input voltage range: 0.7 x Vstart...580 V (min 90 V)
  • Rated DC input voltage: 360 V
  • Rated DC input power: 6200 W
  • Number of independent MPPT : 2
  • Maximum DC input power for each MPPT: 4000 W
  • DC input voltage range with parallel configuration of MPPT at Pacr: 180...530 V
  • DC power limitation with parallel configuration of MPPT: 530 V≤VMPPT≤580 V
  • DC power limitation for each MPPT with independent configuration of MPPT at Pacr, max unbalance example : 4000 W [220 V≤VMPPT≤530 V] the other channel: Pdcr-4000 W [120 V≤VMPPT≤530 V]
  • Maximum DC input current / for each MPPT: 36.0 A / 18.0 A
  • Maximum input short circuit current for each MPPT: 22.0 A
  • Number of DC input pairs for each MPPT: 2
  • DC connection type : PV quick fit connector

OUTPUT

  • AC grid connection type: Single-phase
  • Rated AC power r ([email protected]φ=1): 6000 W
  • Rated AC power ([email protected]φ=±0.9): 6000 W
  • Maximum AC output power: 6000 W
  • Maximum apparent power : 6670 VA
  • Rated AC grid voltage: 230 V
  • AC voltage range: 180...264 V
  • Maximum AC output current: 30.0 A
  • Contributory fault current: 40.0 A
  • Rated output frequency:50 Hz / 60 Hz
  • Output frequency range: 47...53 Hz / 57…63 Hz
  • Nominal power factor and adjustable range : > 0.995, adj. 0.8 inductive to 0.8 capacitive
  • Total current harmonic distortion: < 3.5%
  • AC connection type: Terminal block, cable gland M32

INPUT PROTECTION

  • Reverse polarity protection: Yes, from limited current source
  • Input over voltage protection for each MPPT - varistor: Yes
  • Photovoltaic array isolation control: According to local standard

OUTPUT PROTECTION

  • Anti-islanding protection: According to local standard
  • Maximum external AC overcurrent protection: 40.0 A
  • Output overvoltage protection - varistor : 2 (L - N / L - PE)

AMBIENT

  • Ambient temperature range: -25...+60°C (-13...+ 140°F) with derating above 50°C (122°F)
  • Relative humidity: 0...100% condensing
  • Sound pressure level, typical: 50 dBA @ 1 m
  • Maximum operating altitude without derating: 2000 m / 6560 ft

PHYSICAL

  • Environmental protection rating: IP65
  • Cooling: Natural
  • Dimension (H x W x D): 810 mm x 325 mm x 222 mm
  • Weight : < 26.0 kg
  • Mounting system: Wall bracket

SAFETY

  • Isolation level: Transformerless
  • Marking: CE (50 Hz only), RCM
  • Safety and EMC standard: EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, EN 61000-6-1, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
  • Grid standard: CEI 0-21, DIN V VDE V 0126-1-1, G59/3, EN 50438 (not for all national appendices), RD 1699, RD 413, ITC-BT-40, AS 4777, C10/11, IEC 61727, IEC 62116

   Downloads

Datasheet EN [link]
Manual EN [link]
Guide Installation EN [link]

  Customer service

0882 22 82 47
[email protected]
Path: > > > > > INVERTER ABB 6KW SINGLEPHASE PVI-6000-TL-OUTD ON-GRID EXCHANGE ON SITE

30 other products in the same category: